Patient Log - 2009. Updated 02-23-15.

23 implants placed.

3 failed on the same patient.

Patient #10 (1 implant)

Pre-op x-ray

Post-op x-ray

Most recent x-ray

Failure - No

#5

Immediate placement.

 

2009 12/16

Immediate placement 5 x 8mm implant, old design with thread/fins combination. 5.4mm old design healing abutment was placed same visit.

2013 08/06

3.5 years

 

Patient #9 (1 implant)

Pre-op x-ray

Post-op x-ray

Most recent x-ray

Failure - No

#5

Healed site.

 

2010 03/09

3.5 x 10mm implant, old design with thread/fins combination. 4.2mm old design healing abutment was placed same visit.

2014 10/15

4.5 years

 

Patient #8 (9 implants)

Pre-op x-ray

Post-op x-ray

Most recent x-ray

Failure - No

#2-15

Recent extractions, edentulous maxilla, bilateral sinus grafts.

 

2009 12/04

Multiple old design implants (#4, 5, 6, 7, 10, 11, 12, 13, 14) with thread/fins combination. Old design healing abutments were placed same visit.

2014 09/08

5 years

 

Patient #7 (3 implants)

Pre-op x-ray

Post-op x-ray

Most recent x-ray

Failure - Yes

#26, 27, 28

Healed sites.

 

2009 12/02

26, 27, 28- 3.5 x 12mm implants with old revision healing abutments.

2010 02/15

2 months

See Patient #26 for new implant placement

Implants developed bone loss that was noticed on a 2 month x-ray. Implants were removed, no buccal bone loss or infection was present. Possible failure cause:

- pt. is a heavy smoker and diabetic;

- bone was class I (very hard, possible bone overheating during drilling). Not a likely cause since drilling was done at 50 rpm;

- excessive bone compression during implant placement - most likely cause.

See patient #26 for new implant placement.

Patient #6 (1 implant)

Pre-op x-ray

Post-op x-ray

Most recent x-ray

Failure - No

#7

Healed site.

 

2009 11/23

2.5 x 12mm implant, old design. 4.2mm old design healing abutment was placed same visit.

Patient #5 (1 implant)

Pre-op x-ray

Post-op x-ray

Most recent x-ray

Failure - No

#4

Healed site. 25 year old pt.

 

2009 11/04

3.5 x 10mm implant, old design with thread/fins combination. 4.2mm old design healing abutment was placed same visit.

2012 03/02

2.5 years

 

Patient #4 (1 implant)

Pre-op x-ray

Post-op x-ray

Most recent x-ray

Failure - No

#20

Healed site. 28 year old pt.

 

2009 10/28

3.5 x 10mm implant, old design with thread/fins combination.

2010 08/24

1 year

Out of state pt., no contact.

 

Patient #3 (3 implants)

Pre-op x-ray

Post-op x-ray

Most recent x-ray

Failure - No

#10, 11, 13

Healed sites #11 and 13. Immediate placement #10. 80 year old pt.

 

2009 09/30

3.5 x 10mm implant, old design with thread/fins combination. 4.2mm old design healing abutment was placed same visit.

2012 04/26

3 years

 

Patient #2 (1 implant)

Pre-op x-ray

Post-op x-ray

Most recent x-ray

Failure - No

#19

Healed site. 30 year old female.

 

2009 09/16

3.5 x 10mm implant, old design with thread/fins combination. No healing abutment placed at a time of surgery.

2010 03/15

6 months

Pt. moved, no contact.

 

Patient #1 (1 implant)

Pre-op x-ray

Post-op x-ray

Most recent x-ray

Failure - No

#29

Healed site. 65 year old pt.

 

2009 06/09

3.5 x 10mm implant, old design with thread/fins combination. 4.2mm old design healing abutment was placed same visit.

2014 10/01

5 years

 