2013 Patient Log Updated 03-04-15

Implants placed - 112

Removed: 2 due to fractured temp. bridge; 1 due to insufficient depth of placement (implant integrated well); 1 due to poor soft tissue healing around 8x8 implant (implant integrated well); 1 due to lack of primary stability/surgical error.

Total removed - 5

Removed due to infection - 1

Patient #207 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#13

Immediate placement.

 

2013 12/13

4.3 x 14mm implant

2014 02/17

2 months

Patient #206 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#4

Healed site.

 

2013 12/06

5.0 x 8mm implant same time with sinus augmentation.

2014 05/15

5 months

Patient #205 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#30

Healed site.

 

2013 12/03

3.1 x 12mm implant

2014 05/05

5 months

Patient #204 (2 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#3, 4

Healed sites.

 

2013 11/20

3- 5.0 x 10mm implant

4- 4.3 x 10mm implant

2014 04/24

5 months

Patient #203 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#14

Healed site.

 

2013 11/12

5.0x8mm implant with 5.5mm healing abutment.

2013 04/30

5 months

Patient #202 (2 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

2013-11-12

#5 and 7 implants failed after immediate temporary bridge fractured in #10 area after about 2 months in function. Pt. fractured bridge for two weeks prior to coming to the office. At that point implants 5 and 7 supported bridge 5-9. Implants did not have a chance...

Implants were removed, sites debrided (no buccal bone damage or infection was present).

See case #192 for original placement.

 

2013 11/12

5 x 8 implant was placed in #7; 6.5 x 7 implant was placed in #5;

additional implant (5 x 6) was placed in #3.

A bulkier, less attractive bridge was made to prevent fracture.

2014 05/02

6 months x-ray with final full-contour cemented zirconia bridge.

Patient #201 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#31

Healed site.

 

2013 11/01

5.0 x 8mm implant with 5.5mm healing abutment.

2014 01/09

2 months

Patient #200 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#5

Immediate placement.

 

2013 10/21

3.5 x 10mm implant with 4.7mm healing abutment.

 

2014 03/13

5 months

Patient #199 (2 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#22, 30

Healed sites.

 

2013 10/03

22- 3.0 x 14mm implant with 4.2mm healing abutment

30- 5.0 x 10mm implant

2014 11/08

1 year

Patient #198 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#30

Healed site.

 

2013 09/19

5.0 x 8mm implant with 5.5mm healing abutment.

2013 02/27

5 months

Patient #197 (3 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#8, 9, 12

Immediate placement.

 

2013 09/18

8, 9- 5.0 x 10mm implant with 5.1mm healing abutment

12- 3.5 x 12mm implant with 4.2mm healing abutment

2013 12/06

3 months

Patient #196 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#9

Healed site. Large amount of buccal bone loss. Cortical bone allograft was placed same visit with extraction.

 

2013 09/05

3.5 x 12mm implant with 4.7mm temporary abutment crown.

A temporary crown was fabricated the same visit.

2014 03/03

6 months

Patient #195 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#30

Immediate placement.

 

2013 08/27

5.0 x 10mm implant with 5.1mm healing abutment.

Should have placed this implant deeper (about 1mm), see crestal bone remodeling in most recent x-ray.

2014 04/15

8 months

Patient #194 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#8

Healed site.

 

2013 08/19

3.5 x 12mm implant with 4.2mm temporary abutment crown.

A temporary crown was fabricated the same visit. Very thin ridge, large amount of palatal bone loss due to "difficult extraction" per pt. Bone spreading was done with buccal plate green stick fracture.

2014 04/28

8 months

Notice crestal bone loss due to thin ridge and buccal plate fracture. Fortunately pt. has thick gingival biotype - final restoration looks very good. Will monitor crestal bone level.

Patient #193 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#31

Healed site

 

2013 08/15

5.0 x 8mm implant with 5.1mm healing abutment.

2014 08/12

1 year

Patient #192 (5 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - Yes - 2

#5, 7, 10, 11, 13

13- Healed site.

5, 7, 10, 11- Immediate placement.

 

2013 08/09

5- 5.0 x 12mm implant with 4.6mm Closed Tray Abutment

7, 10- 4.3 x 10mm implant with 4.2mm Closed Tray Abutment

11- 4.3 x 12mm implant with 4.6mm Closed Tray Abutment

13- 4.3 x 10mm implant with 4.6mm Closed Tray Abutment

2014 05/02

9 months

2013-11-12

#5 and 7 implants failed after immediate temporary bridge fractured in #10 area after about 2 months in function. Pt. fractured bridge for two weeks prior to coming to the office. At that point implants 5 and 7 supported bridge 5-9. Implants did not have a chance...

Implants were removed, sites debrided (no buccal bone damage or infection was present).

See case #202 for replacement of these implants as well as additional #3 implant placement.

Patient #191 (6 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#19, 29, 24, 25, 29, 30

20, 29- Healed sites

19, 24, 25, 30- Immediate placement

 

2013 07/29

19, 30- 5.0 x 8mm implant with 5.0 x 6.5mm prepable abutment

20- 5.0 x 10mm implant with 4.6 x 6.5mm prepable abutment

24, 25- 2.5 x 14mm tom-KAT implant with 4.2 x 6.5mm contoured abutment

29- 4.3 x 10mm implant with 4.6 x 6.5mm prepable abutment

 

A temporary bridge was fabricated the same visit

2014 05/02

10 months

Patient #190 (5 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#3, 4, 5, 8, 9

3, 4, 5- Healed site

8, 9-  Immediate placement

 

2013 07/18

3- 3.5 x 8mm implant with 4.2 x 6.5mm prepable abutment

4- 2.5 x 10mm tom-KAT implant with 4.2 x 6.5mm prepable abutment

5- 2.5 x 12mm tom-KAT implant with 4.2 x 6.5mm prepable abutment

8, 9- 4.3 x 10mm implant with 4.6 x 10° angled abutment

 

A temporary bridge was fabricated the same visit.

2014 03/14

8 months

Patient #189 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#19

Healed site

 

2013 07/17

5.0 x 8mm implant with 5.1mm healing abutment

2013 11/25

4 months

Patient #188 (2 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - Yes 1

#18, 31

Immediate placement

 

2013 07/11

18- 5.0 x 8mm implant

31- 8.0 x 8mm implant

2014 05/15

1 year

#31 was removed on 7/14/14. Gum tissue was not healing properly. 8 x 8 mm implant was integrated.

Patient #187 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#30

Immediate placement.

 

2013 06/25

6.5 x 7mm implant with 5.5mm healing abutment

2014 11/03

1 year

Patient #186 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#15

Immediate placement.

 

2013 06/10

5.0 x 6mm implant with 5.1mm healing abutment

2014 05/15

1 year

Patient #185 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#3

Healed site.

 

2013 06/20

4.3 x 8mm implant with 5.1mm healing abutment

2013 08/27

2 months

Patient #184 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#13

Immediate placement. See case #169 for description of initial placement. #13 implant was removed due to thread exposure on distal surface. This happened because #13 implant was not placed deep enough. Because implant was placed at the same time with #14 extraction, significant amount of bone remodeling should have been anticipated.

Replacement implant was the same size, it was placed 2mm deeper and was included in a temporary bridge.

 

2013 06/10

3.5 x 12mm implant with 5.1mm healing abutment

2014 11/03

1 year

Patient #183 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#14

Healed site.

 

2013 06/14

5.0 x 6mm implant with 5.5mm healing abutment

2014 09/18

1.5 years

Patient #182 (6 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#4, 5, 19, 20, 21, 22

Healed sites.

 

2013 06/10

4- 4.3 x 8mm implant with 4.7mm healing abutment

5- 4.3 x 10mm implant with 4.7mm healing abutment

19- 3.5 x 8mm implant with 4.7mm healing abutment

20- 3.1 x 14mm tom-KAT implant with 4.2mm healing abutment

21- 3.1 x 12mm tom-KAT implant with 4.2mm healing abutment

22- 3.1 x 14mm tom-KAT implant with 4.2mm healing abutment

2014 10/20

1.5 years

Patient #181 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#4

Healed site.

 

2013 06/03

4.3 x 8mm implant with 4.2mm healing abutment.

2013 09/19

3 months

Patient #180 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#31

Immediate placement.

 

2013 05/29

5.0 x 8mm implant with 5.5mm healing abutment.

2014 07/29

1 year

Patient #179 (2 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#29, 30

Healed sites.

 

2013 05/28

29- 3.5 x 10mm implant.

30- 4.3 x 8mm implant.

2013 09/25

4 months

Patient #178 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#12

Immediate placement.

 

2013 05/21

5.0 x 10mm implant with 4.2mm temporary abutment crown.

A temporary crown was fabricated the same visit.

2014 10/09

1.5 years

Patient #177 (3 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#2, 3, 4

Healed sites.

 

2013 05/13

2- 5.0 x 6mm implant with 5.5mm healing abutment.

3- 4.3 x 10mm implant with 5.5mm healing abutment.

4- 3.0 x 10mm implant with 4.2mm healing abutment.

2013 11/11

6 months

Patient #176 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#12

Healed site.

 

2013 04/29

5.0 x 10mm implant

2014 10/09

1.5 years

Patient #175 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#19

Healed site.

 

2013 04/16

3.0 x 12mm implant with 5.1mm healing abutment.

2014 01/27

9 months

Patient #174 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#12

Healed site.

 

2013 04/12

3.5 x 12mm implant with 4.7mm healing abutment.

2014 04/15

1 year

Patient #173 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#7

Healed site.

 

2013 04/11

2.5 x 14mm implant with 4.2mm temporary abutment crown.

A temporary crown was fabricated the same visit.

2013 09/30

5 months

Patient #172 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#3 Healed site.

8 x 8mm implant was removed (unscrewed with large amount of torque) due to poor soft tissue response. Site was grafted and allowed to heal for 6 months.

#3 implant was originally placed on 7/2/2012 (see case #131).

 

2013 04/09

5.0 x 8mm implant with 5.1mm healing abutment.

2014 07/17

1 year

Patient #171 (2 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#5, 14

5- Healed site.

14- Immediate placement.

 

2013 04/02

5- 5.0 x 12mm implant with 4.7mm healing abutment.

14- 8 x 8mm implant.

5- 2013 09/18

     5 months

 

14- 2013 12/16

     8 months

Patient #170 (3 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#3, 4, 5

3, 4- Healed sites.

5- Immediate placement.

 

2013 04/01

3- 4.3 x 10mm implant with 5.5mm healing abutment.

4- 4.3 x 10mm implant with 4.7mm healing abutment.

5- 3.5 x 12mm implant with 4.7mm healing abutment.

2014 08/28

1.5 years

Patient #169 (3 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#28, 29, 30

28, 30- Immediate placement.

29- Healed site.

 

2013 03/26

28, 29- 3.5 x 8mm implant.

30- 6.5 x 7mm implant.

2014 09/23

1.5 years

#28 x-ray has not been taken, will be updated. See #28 x-ray on the right (taken 08-08-13)

Patient #168 (7 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - Yes 1

#3, 4, 5, 8, 9, 13, 14

3, 4, 13- Healed site.

5, 8, 9, 14- Immediate placement.

 

2013 03/20

3, 14- 5.0 x 6mm implant

4- 3.5 x 8mm implant with 4.2mm closed tray abutment.

5- 4.3 x 10mm implant with 4.6mm closed tray abutment.

8, 9- 5.0 x 12mm implant with 5.4mm closed tray abutment.

13- 3.5 x 12mm implant with 4.6mm closed tray abutment.

A temporary bridge was fabricated and cemented over implants with temporary cement around the margins the same visit.

2013 11/03

2 years

#13 was removed and replaced on 06/19/2013 due to 2mm bone loss. #13 was not placed deep enough (was placed in a healed site), excessive bone loss happened because of bone remodeling around #14 implant (placed in a fresh extraction socket). Implant was unscrewed and new implant of the same dimensions was placed 2-3mm deeper. No infection was present. (see case #184)

Patient #167 (2 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#30, 31

Healed sites.

 

2013 03/18

30- 5.0 x 8mm implant with 5.5mm healing abutment.

31- 5.0 x 6mm implant with 5.5mm healing abutment.

2013 09/16

6 months

Patient #166 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#11

Immediate placement.

 

2013 03/18

5.0 x 12mm implant with 4.7mm healing abutment.

2013 07/29

4 months

Patient #165 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#7

Immediate placement

 

2013 03/08

3.0 x 12mm implant with 4.2mm temporary abutment.

A temporary crown was fabricated the same visit.

2013 06/06

3 months

Patient #164 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#20

Healed site.

 

2013 02/20

5.0 x 8mm implant with 4.7mm healing abutment.

2014 05/06

1 year

Patient #163 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - Yes

#4

Immediate placement.

 

2013 02/08

4.3 x 6mm implant with 4.2mm healing abutment.

2013 02/28

20 days

Likely cause of failure:

- insufficient primary stability (implant placed with finger pressure only);

- healing abutment was tapped on the implant without the use of placement instrument and without bone reaming. Implant possibly became even more loose because of healing abutment's contact with bone.

Conclusion:

When primary stability is not sufficient, two-stage surgery has to be done. Bone reaming is critical even during immediate implant placement.

Patient #162 (4 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#2, 3, 4, 5

2, 5- Immediate placement.

3, 4- Healed sites.

 

2013 02/07

2- 6.5 x 7mm implant with 6.5mm healing abutment.

3- 5.0 x 6mm implant with 5.1mm healing abutment.

4- 3.5 x 8mm implant with 4.2mm healing abutment.

5- 4.3 x 10mm implant with 4.2mm healing abutment.

2014 09/02

1.5 years

Patient #161 (4 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#5, 6, 8, 11

Healed sites

 

2013 01/31

5, 6, 11- 4.3 x 12mm implant

8- 3.5 x 14mm implant

2013 04/24

3 months

Patient #160 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#5

Healed site.

    #5 implant was removed due to bone loss on 8/17/12. See case #134

 

2013 01/28

4.3 x 12mm implant with 4.7mm healing abutment.

2013 06/06

6 monts

Patient #159 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#3

Healed site.

 

2013 01/21

5.0 x 6mm implant

2014 09/18

2 years

Pt. still has a temp. crown

Patient #158 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#12

Healed site.

 

2013 01/18

3.5 x 12mm implant with 4.7mm healing abutment.

2013 05/02

4 months

Patient #157 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#3

Healed site.

 

2013 01/15

5.0 x 8mm implant.

2013 03/21

2 months

Patient #156 (2 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#29, 30

Healed sites.

 

2013 01/15

29- 3.5 x 10mm implant with 5.1mm healing abutment.

30- 3.5 x 8mm implant with 5.1mm healing abutment.

2015 02/17

2 years

Patient #155 (2 implants)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#29, 30

Healed sites.

 

2013 01/10

29- 4.3 x 8mm implant with 5.5mm healing abutment.

30- 5.0 x 8mm implant with 5.5mm healing abutment.

2013 06/19

5 months

Patient #154 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#31

Healed site, extraction was done 6 month prior to implant placement.

 

2013 01/09

4.3 x 8mm implant with 5.1mm healing abutment.

2014 09/15

2 years

Patient #153 (1 implant)

Pre-op xray

Post-op x-ray

Most recent x-ray

Failure - No

#19

Healed site.

 

2013 01/03

3.5 x 10mm implant with 5.1mm healing abutment.

2013 05/02

4 months

Invented and made in USA. US Patents 8,398,400, 8,469,710 and 8,734,155. EU Patent 2046238.